Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
J Diabetes Sci Technol ; : 19322968241242803, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38613227

RESUMO

BACKGROUND: CamAPS HX fully closed-loop (FCL) system, with no user input required at mealtimes, has been shown to be safe and effective in adults with type 1 and type 2 diabetes. We assessed whether time spent in hypoglycemia and hyperglycemia during FCL insulin delivery in adults varied by type of diabetes over the 24-hour period. METHODS: We retrospectively analyzed eight weeks of data from 52 participants (adults with type 1 diabetes and adults with insulin-treated type 2 diabetes) recruited to two single-center randomized controlled studies using FCL insulin delivery during unrestricted-living conditions. Key outcomes were time spent in hypoglycemia <70 mg/dL and marked hyperglycemia >300 mg/dL by type of diabetes. RESULTS: The median percentage of time spent in hypoglycemia <70 mg/dL over the 24-hour period was lower for those with type 2 diabetes than for those with type 1 diabetes (median [interquartile range (IQR)] 0.43% [0.20-0.77] vs 0.86%, [0.54-1.46]; mean difference 0.46 percentage points [95% CI 0.23-0.70]; P < .001). Median percentage time in marked hyperglycemia >300 mg/dL was lower for those with type 2 diabetes than for those with type 1 diabetes (median [IQR] 1.8% [0.6-3.5] vs 9.3% [6.9-11.8]; mean difference 7.8 percentage points [95% CI 5.5-10.0]; P < .001). CONCLUSIONS: Using the FCL system, hypoglycemia and marked hyperglycemia exposure were lower in type 2 diabetes than in type 1 diabetes.

2.
Diabetes Technol Ther ; 26(3): 198-202, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38444312

RESUMO

The presence of diabetic ketoacidosis (DKA) at diagnosis of type 1 diabetes (T1D) is associated with higher glycated hemoglobin levels over time. We evaluated whether hybrid-closed loop (HCL) therapy from onset of T1D could prevent the adverse impact of DKA at diagnosis on long-term glycemic outcomes. This was a posthoc analysis from 51 adolescents using HCL from diagnosis of T1D as part of the CLOuD trial (NCT02871089). We compared glycemic and insulin metrics between adolescents with (n = 17) and without (n = 34) DKA at diagnosis. Participants with and without DKA at diagnosis had similar time in target glucose range 3.9-10.0 mmol/L (70-180 mg/dL), time below range (<3.9 mmol/L, <70 mg/dL) and HbA1c at 6, 12, and 24 months. While insulin requirements at 6 months were higher in those with DKA at diagnosis, this was not statistically significant after adjusting for bodyweight. Residual C-peptide secretion was similar between groups. We conclude that HCL therapy may mitigate against the negative glycemic effects of DKA at T1D diagnosis.


Assuntos
Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Adolescente , Humanos , Insulina/uso terapêutico , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/tratamento farmacológico , Cetoacidose Diabética/etiologia , Glicemia , Sistemas de Infusão de Insulina , Insulina Regular Humana
3.
J Diabetes Sci Technol ; : 19322968241231950, 2024 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-38494876

RESUMO

BACKGROUND/OBJECTIVE: The main objective of this study is to evaluate the incremental cost-effectiveness (ICER) of the Cambridge hybrid closed-loop automated insulin delivery (AID) algorithm versus usual care for children and adolescents with type 1 diabetes (T1D). METHODS: This multicenter, binational, parallel-controlled trial randomized 133 insulin pump using participants aged 6 to 18 years to either AID (n = 65) or usual care (n = 68) for 6 months. Both within-trial and lifetime cost-effectiveness were analyzed. Analysis focused on the treatment subgroup (n = 21) who received the much more reliable CamAPS FX hardware iteration and their contemporaneous control group (n = 24). Lifetime complications and costs were simulated via an updated Sheffield T1D policy model. RESULTS: Within-trial, both groups had indistinguishable and statistically unchanged health-related quality of life, and statistically similar hypoglycemia, severe hypoglycemia, and diabetic ketoacidosis (DKA) event rates. Total health care utilization was higher in the treatment group. Both the overall treatment group and CamAPS FX subgroup exhibited improved HbA1C (-0.32%, 95% CI: -0.59 to -0.04; P = .02, and -1.05%, 95% CI: -1.43 to -0.67; P < .001, respectively). Modeling projected increased expected lifespan of 5.36 years and discounted quality-adjusted life years (QALYs) of 1.16 (U.K. tariffs) and 1.52 (U.S. tariffs) in the CamAPS FX subgroup. Estimated ICERs for the subgroup were £19 324/QALY (United Kingdom) and -$3917/QALY (United States). For subgroup patients already using continuous glucose monitors (CGM), ICERs were £10 096/QALY (United Kingdom) and -$33 616/QALY (United States). Probabilistic sensitivity analysis generated mean ICERs of £19 342/QALY (95% CI: £15 903/QALY to £22 929/QALY) (United Kingdom) and -$28 283/QALY (95% CI: -$59 607/QALY to $1858/QALY) (United States). CONCLUSIONS: For children and adolescents with T1D on insulin pump therapy, AID using the Cambridge algorithm appears cost-effective below a £20 000/QALY threshold (United Kingdom) and cost saving (United States).

4.
Diabetes Technol Ther ; 26(4): 211-221, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38426909

RESUMO

Introduction: The Closing the Loop in Adults With Type 1 Diabetes (CLEAR) randomized crossover study compared a novel fully closed-loop insulin delivery system with no carbohydrate entry or mealtime bolusing (CamAPS HX), with standard insulin pump therapy and glucose sensor in adults with type 1 diabetes and suboptimal glycemic outcomes. This qualitative substudy aimed to understand the psychosocial impact of using the fully automated system. Materials and Methods: Adults participating in the CLEAR study were invited to take part in a virtual semistructured interview after they had completed 8 weeks using the fully closed-loop system. Recruitment continued until there was adequate representation and data saturation occurred. Interviews were anonymized and transcribed for in-depth thematic analysis using an inductive-deductive approach. Study participants were also asked to complete questionnaires assessing diabetes distress, hypoglycemia confidence, and closed-loop treatment satisfaction. Results: Eleven participants (eight male and three female; age range 26-66 years) were interviewed. After an initial adjustment period, interviewees reported enjoying a reduction in diabetes burden, freed-up mental capacity, and improved mood. All were happy with overnight glycemic outcomes, with the majority reporting benefits on sleep. Although experiences of postprandial glucose outcomes varied, all found mealtimes easier and less stressful, particularly when eating out. Negatives raised by participants predominantly related to the insulin pump hardware, but some also reported increased snacking and challenges around resuming carbohydrate counting at trial closeout. Conclusions: In adults with type 1 diabetes, use of a fully closed-loop insulin delivery system had significant quality-of-life benefits and provided a welcome break from the day-to-day demands of living with diabetes. Clinical Trial Registration: NCT04977908.


Assuntos
Diabetes Mellitus Tipo 1 , Insulina , Adulto , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Insulina/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/psicologia , Glicemia , Hipoglicemiantes/uso terapêutico , Estudos Cross-Over , Resultado do Tratamento , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico
5.
Artigo em Inglês | MEDLINE | ID: mdl-38315506

RESUMO

Objective: To evaluate postprandial glucose control when applying (1) faster-acting insulin aspart (Fiasp) compared to insulin aspart and (2) ultra-rapid insulin lispro (Lyumjev) compared to insulin lispro using the CamAPS FX hybrid closed-loop algorithm. Research Design and Methods: We undertook a secondary analysis of postprandial glucose excursions from two double-blind, randomized, crossover hybrid closed-loop studies contrasting Fiasp to standard insulin aspart, and Lyumjev to standard insulin lispro. Endpoints included incremental area under curve (iAUC)-2h, iAUC-4h, 4 h postprandial time in target range, time above range, and time below range. It was approved by independent research ethics committees. Results: Two trials with 8 weeks of data from 51 adults with type 1 diabetes were analyzed and 7137 eligible meals were included. During Lyumjev compared with insulin lispro, iAUC-2h and iAUC-4h were significantly decreased following breakfast (mean difference 92 mmol/L per 2 h (95% confidence interval [CI]: 56 to 127); P < 0.001 and 151 mmol/L per 4 h (95% CI: 74 to 229); P < 0.001, respectively) and the evening meal (P < 0.001 and P = 0.011, respectively). Mean time in target range (3.9-10.0 mmol/L) for 4 h postprandially significantly increased during Lyumjev with a mean difference of 6.7 percentage points (95% CI: 3.3 to 10) and 5.7 percentage points (95% CI: 1.4 to 9.9) for breakfast and evening meal, respectively. In contrast, there were no significant differences in iAUC-2h, iAUC-4h, and the other measures of postprandial glucose control between insulin aspart and Fiasp during breakfast, lunch, and evening meal (P > 0.05). Conclusion: The use of Lyumjev with CamAPS FX closed-loop system improved postprandial glucose excursions compared with insulin lispro, while the use of Fiasp did not provide any advantage compared with insulin aspart. Clinical Trial Registration numbers: NCT04055480, NCT05257460.

6.
Diabetes Technol Ther ; 25(12): 856-863, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37823892

RESUMO

Introduction: To evaluate hybrid closed-loop with ultra-rapid insulin lispro (Lyumjev) compared with hybrid closed-loop with standard insulin lispro in adults with type 1 diabetes. Materials and Methods: In a single-center, double-blind, randomized, crossover study, 28 adults with type 1 diabetes (mean ± standard deviation [SD]: age 44.5 ± 10.7 years, glycated hemoglobin (HbA1c) 7.1 ± 0.9% [54 ± 10 mmol/mol]) underwent two 8-week periods comparing hybrid closed-loop with ultra-rapid insulin lispro and hybrid closed-loop with standard insulin lispro in random order. The same CamAPS FX closed-loop algorithm was used in both periods. Results: In an intention-to-treat analysis, the proportion of time sensor glucose was in target range (3.9-10 mmol/L [70-180 mg/dL]; primary endpoint) was greater with ultra-rapid lispro compared with standard insulin lispro (mean ± SD: 78.7 ± 9.8% vs. 76.2 ± 9.6%; mean difference 2.5 percentage points [95% confidence interval 0.8 to 4.2]; P = 0.005). Mean sensor glucose was lower with ultra-rapid lispro compared with standard insulin lispro (7.9 ± 0.8 mmol/L [142 ± 14 mg/dL] vs. 8.1 ± 0.9 mmol/L [146 ± 16 mg/dL]; P = 0.048). The proportion of time with sensor glucose <3.9 mmol/L [70 mg/dL] was similar between interventions (median [interquartile range] ultra-rapid lispro 2.3% [1.3%-2.7%] vs. standard insulin lispro 2.1% [1.4%-3.3%]; P = 0.33). No severe hypoglycemia or ketoacidosis occurred. Conclusions: The use of ultra-rapid lispro with CamAPS FX hybrid closed-loop increases time in range and reduces mean glucose with no difference in hypoglycemia compared with standard insulin lispro in adults with type 1 diabetes. ClinicalTrials.gov: Trial registration number NCT05257460.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Humanos , Adulto , Pessoa de Meia-Idade , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina Lispro/uso terapêutico , Hipoglicemiantes/uso terapêutico , Estudos Cross-Over , Insulina/uso terapêutico , Glicemia , Sistemas de Infusão de Insulina , Hipoglicemia/tratamento farmacológico , Glucose
7.
Diabetes Care ; 46(11): 1916-1922, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37616583

RESUMO

OBJECTIVE: We evaluated the safety and efficacy of fully closed-loop with ultrarapid insulin lispro in adults with type 1 diabetes and suboptimal glycemic control compared with insulin pump therapy with continuous glucose monitoring (CGM). RESEARCH DESIGN AND METHODS: This single-center, randomized, crossover study enrolled 26 adults with type 1 diabetes using insulin pump therapy with suboptimal glycemic control (mean ± SD, age 41 ± 12 years, HbA1c 9.2 ± 1.1% [77 ± 12 mmol/mol]). Participants underwent two 8-week periods of unrestricted living to compare fully closed-loop with ultrarapid insulin lispro (CamAPS HX system) with insulin pump therapy with CGM in random order. RESULTS: In an intention-to-treat analysis, the proportion of time glucose was in range (primary end point 3.9-10.0 mmol/L) was higher during closed-loop than during pump with CGM (mean ± SD 50.0 ± 9.6% vs. 36.2 ± 12.2%, mean difference 13.2 percentage points [95% CI 9.5, 16.9], P < 0.001). Time with glucose >10.0 mmol/L and mean glucose were lower during closed-loop than during pump with CGM (mean ± SD time >10.0 mmol/L: 49.0 ± 9.9 vs. 62.9 ± 12.6%, mean difference -13.3 percentage points [95% CI -17.2, -9.5], P < 0.001; mean ± SD glucose 10.7 ± 1.1 vs. 12.0 ± 1.6 mmol/L, mean difference -1.2 mmol/L [95% CI -1.8, -0.7], P < 0.001). The proportion of time with glucose <3.9 mmol/L was similar between periods (median [interquartile range (IQR)] closed-loop 0.88% [0.51-1.55] vs. pump with CGM 0.64% [0.28-1.10], P = 0.102). Total daily insulin requirements did not differ (median [IQR] closed-loop 51.9 units/day [35.7-91.2] vs. pump with CGM 50.7 units/day [34.0-70.0], P = 0.704). No severe hypoglycemia or ketoacidosis occurred. CONCLUSIONS: Fully closed-loop insulin delivery with CamAPS HX improved glucose control compared with insulin pump therapy with CGM in adults with type 1 diabetes and suboptimal glycemic control.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Adulto , Pessoa de Meia-Idade , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Glicemia , Estudos Cross-Over , Automonitorização da Glicemia , Insulina Lispro/uso terapêutico , Resultado do Tratamento , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico
9.
Diabetes Technol Ther ; 25(7): 485-491, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37229591

RESUMO

Objective: We aimed to assess whether percentage of time spent in hypoglycemia during closed-loop insulin delivery differs by age group and time of day. Methods: We retrospectively analyzed data from hybrid closed-loop studies involving young children (2-7 years), children and adolescents (8-18 years), adults (19-59 years), and older adults (≥60 years) with type 1 diabetes. Main outcome was time spent in hypoglycemia <3.9 mmol/L (<70 mg/dL). Eight weeks of data for 88 participants were analyzed. Results: Median time spent in hypoglycemia over the 24-h period was highest in children and adolescents (4.4% [interquartile range 2.4-5.0]) and very young children (4.0% [3.4-5.2]), followed by adults (2.7% [1.7-4.0]), and older adults (1.8% [1.2-2.2]); P < 0.001 for difference between age groups. Time spent in hypoglycemia during nighttime (midnight-05:59) was lower than during daytime (06:00-23:59) across all age groups. Conclusion: Time in hypoglycemia was highest in the pediatric age group during closed-loop insulin delivery. Hypoglycemia burden was lowest overnight across all age groups.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Adolescente , Idoso , Criança , Pré-Escolar , Humanos , Glicemia , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/induzido quimicamente , Hipoglicemia/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina/efeitos adversos , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem , Adulto , Pessoa de Meia-Idade
10.
Diabetes Technol Ther ; 25(6): 431-436, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36880866

RESUMO

We evaluated the use of hybrid closed-loop (HCL) insulin delivery with faster insulin aspart (Fiasp) in very young children with type 1 diabetes (T1D). In a double-blind, multicenter, randomized, crossover study, children aged 2-6 years with T1D underwent two 8-week periods of HCL using CamAPS FX with Fiasp and standard insulin aspart (IAsp), in random order. Primary endpoint was between-treatment difference in time in target range 3.9-10.0 mmol/L. We randomized 25 participants: mean (±standard deviation) age 5.1 ± 1.3 years, baseline HbA1c 55 ± 9 mmol/mol. Time in range was not significantly different between interventions (64% ± 9% vs. 65% ± 9% for HCL with Fiasp vs. IAsp; mean difference -0.33% [95% confidence interval: -2.13 to 1.47; P = 0.71]). There was no significant difference in time with glucose <3.9 mmol/L. No post-randomization severe hypoglycemia or diabetic ketoacidosis events occurred. Use of Fiasp with CamAPS FX HCL demonstrated no significant difference in glycemic outcomes compared with IAsp in very young children with T1D. Clinical trials registration: NCT04759144.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Criança , Pré-Escolar , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina Aspart/uso terapêutico , Hipoglicemiantes/uso terapêutico , Estudos Cross-Over , Glicemia , Insulina/uso terapêutico , Método Duplo-Cego
11.
J Diabetes Sci Technol ; : 19322968221141924, 2022 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-36475908

RESUMO

OBJECTIVE: Many hybrid closed-loop (HCL) systems struggle to manage unusually high glucose levels as experienced with intercurrent illness or pre-menstrually. Manual correction boluses may be needed, increasing hypoglycemia risk with overcorrection. The Cambridge HCL system includes a user-initiated algorithm intensification mode ("Boost"), activation of which increases automated insulin delivery by approximately 35%, while remaining glucose-responsive. In this analysis, we assessed the safety of "Boost" mode. METHODS: We retrospectively analyzed data from closed-loop studies involving young children (1-7 years, n = 24), children and adolescents (10-17 years, n = 19), adults (≥24 years, n = 13), and older adults (≥60 years, n = 20) with type 1 diabetes. Outcomes were calculated per participant for days with ≥30 minutes of "Boost" use versus days with no "Boost" use. Participants with <10 "Boost" days were excluded. The main outcome was time spent in hypoglycemia <70 and <54 mg/dL. RESULTS: Eight weeks of data for 76 participants were analyzed. There was no difference in time spent <70 and <54 mg/dL between "Boost" days and "non-Boost" days; mean difference: -0.10% (95% confidence interval [CI] -0.28 to 0.07; P = .249) time <70 mg/dL, and 0.03 (-0.04 to 0.09; P = .416) time < 54 mg/dL. Time in significant hyperglycemia >300 mg/dL was 1.39 percentage points (1.01 to 1.77; P < .001) higher on "Boost" days, with higher mean glucose and lower time in target range (P < .001). CONCLUSIONS: Use of an algorithm intensification mode in HCL therapy is safe across all age groups with type 1 diabetes. The higher time in hyperglycemia observed on "Boost" days suggests that users are more likely to use algorithm intensification on days with extreme hyperglycemic excursions.

12.
J Diabetes Sci Technol ; : 19322968221145184, 2022 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-36540007

RESUMO

BACKGROUND: CamAPS FX is a hybrid closed-loop smartphone app used to manage type one diabetes. The closed-loop algorithm has a default target glucose of 5.8 mmol/L (104.5 mg/dL), but users can select personal glucose targets (adjustable between 4.4 mmol/L and 11.0 mmol/L [79 mg/dL and 198 mg/dL, respectively]). METHOD: In this post-hoc analysis, we evaluated the impact of personal glucose targets on glycemic control using data from participants in five randomized controlled trials. RESULTS: Personal glucose targets were widely used, with 20.3% of all days in the data set having a target outside the default target bin (5.5-6.0 mmol/L [99-108 mg/dL]). Personal glucose targets >6.5 mmol/L (117 mg/dL) were associated with significantly less time in target range (3.9-10.0 mmol/L [70-180 mg/dL]; 6.5-7.0 mmol/L [117-126 mg/dL]: mean difference = -3.2 percentage points [95% CI: -5.3 to -1.2; P < .001]; 7.0-7.5 mmol/L [126-135 mg/dL]: -10.8 percentage points [95% CI: -14.1 to -7.6; P < .001]). Personal targets >6.5 mmol/L (117 mg/dL) were associated with significantly lower time (<3.9 mmol/L [<70 mg/dL]; 6.5-7.0 mmol/L [117-126 mg/dL]: -1.85 percentage points [95% CI: -2.37 to -1.34; P < .001]; 7.0-7.5 mmol/L [126-135 mg/dL]: -2.68 percentage points [95% CI: -3.49 to -1.86; P < .001]). CONCLUSIONS: Discrete study populations showed differences in glucose control when applying similar personal targets.

13.
Diabetes Care ; 2022 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-36350787

RESUMO

OBJECTIVE: To evaluate the impact of CamAPS FX hybrid closed-loop (HCL) automated insulin delivery in very young children with type 1 diabetes (T1D) on caregivers' well-being, fear of hypoglycemia, and sleepiness. RESEARCH DESIGN AND METHODS: We conducted a multinational, open-label, randomized crossover study. Children (age 1-7 years) with T1D received treatment for two 4-month periods in random order, comparing HCL with sensor augmented pump (control). At baseline and after each treatment period, caregivers were invited to complete World Health Organization-Five Well-Being Index, Hypoglycemia Fear Survey, and Epworth Sleepiness Scale questionnaires. RESULTS: Caregivers of 74 children (mean ± SD age 5 ± 2 years and baseline HbA1c 7.3 ± 0.7%; 42% female) participated. Results revealed significantly lower scores for hypoglycemia fear (P < 0.001) and higher scores for well-being (P < 0.001) after HCL treatment. A trend toward a reduction in sleepiness score was observed (P = 0.09). CONCLUSIONS: Our results suggest better well-being and less hypoglycemia fear in caregivers of very young children with T1D on CamAPS FX HCL.

14.
N Engl J Med ; 387(10): 882-893, 2022 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-36069870

RESUMO

BACKGROUND: Whether improved glucose control with hybrid closed-loop therapy can preserve C-peptide secretion as compared with standard insulin therapy in persons with new-onset type 1 diabetes is unclear. METHODS: In a multicenter, open-label, parallel-group, randomized trial, we assigned youths 10.0 to 16.9 years of age within 21 days after a diagnosis of type 1 diabetes to receive hybrid closed-loop therapy or standard insulin therapy (control) for 24 months. The primary end point was the area under the curve (AUC) for the plasma C-peptide level (after a mixed-meal tolerance test) at 12 months after diagnosis. The analysis was performed on an intention-to-treat basis. RESULTS: A total of 97 participants (mean [±SD] age, 12±2 years) underwent randomization: 51 were assigned to receive closed-loop therapy and 46 to receive control therapy. The AUC for the C-peptide level at 12 months (primary end point) did not differ significantly between the two groups (geometric mean, 0.35 pmol per milliliter [interquartile range, 0.16 to 0.49] with closed-loop therapy and 0.46 pmol per milliliter [interquartile range, 0.22 to 0.69] with control therapy; mean adjusted difference, -0.06 pmol per milliliter [95% confidence interval {CI}, -0.14 to 0.03]). There was not a substantial between-group difference in the AUC for the C-peptide level at 24 months (geometric mean, 0.18 pmol per milliliter [interquartile range, 0.06 to 0.22] with closed-loop therapy and 0.24 pmol per milliliter [interquartile range, 0.05 to 0.30] with control therapy; mean adjusted difference, -0.04 pmol per milliliter [95% CI, -0.14 to 0.06]). The arithmetic mean glycated hemoglobin level was lower in the closed-loop group than in the control group by 4 mmol per mole (0.4 percentage points; 95% CI, 0 to 8 mmol per mole [0.0 to 0.7 percentage points]) at 12 months and by 11 mmol per mole (1.0 percentage points; 95% CI, 7 to 15 mmol per mole [0.5 to 1.5 percentage points]) at 24 months. Five cases of severe hypoglycemia occurred in the closed-loop group (in 3 participants), and one occurred in the control group; one case of diabetic ketoacidosis occurred in the closed-loop group. CONCLUSIONS: In youths with new-onset type 1 diabetes, intensive glucose control for 24 months did not appear to prevent the decline in residual C-peptide secretion. (Funded by the National Institute for Health and Care Research and others; CLOuD ClinicalTrials.gov number, NCT02871089.).


Assuntos
Peptídeo C , Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Insulina , Adolescente , Glicemia/análise , Peptídeo C/metabolismo , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/metabolismo , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina
15.
Diabetes Obes Metab ; 24(12): 2309-2318, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35837984

RESUMO

AIM: To examine changes in the lived experience of type 1 diabetes after use of hybrid closed loop (CL), including the CamAPS FX CL system. MATERIALS AND METHODS: The primary study was conducted as an open-label, single-period, randomized, parallel design contrasting CL versus insulin pump (with or without continuous glucose monitoring). Participants were asked to complete patient-reported outcomes before starting CL and 3 and 6 months later. Surveys assessed diabetes distress, hypoglycaemia concerns and quality of life. Qualitative focus group data were collected at the completion of the study. RESULTS: In this sample of 98 youth (age range 6-18, mean age 12.7 ± 2.8 years) and their parents, CL use was not associated with psychosocial benefits overall. However, the subgroup (n = 12) using the CamAPS FX system showed modest improvements in quality of life and parent distress, reinforced by both survey (p < .05) and focus group responses. There were no negative effects of CL use reported by study participants. CONCLUSIONS: Closed loop use via the CamAPS FX system was associated with modest improvements in aspects of the lived experience of managing type 1 diabetes in youth and their families. Further refinements of the system may optimize the user experience.


Assuntos
Diabetes Mellitus Tipo 1 , Adolescente , Humanos , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Automonitorização da Glicemia , Insulina/uso terapêutico , Qualidade de Vida , Hipoglicemiantes/uso terapêutico , Glicemia , Resultado do Tratamento , Sistemas de Infusão de Insulina , Pais/psicologia
16.
Pediatr Diabetes ; 23(6): 799-808, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35561092

RESUMO

OBJECTIVES: We explored parents' views about healthcare professionals having remote access to their young child's insulin and glucose data during a clinical trial to inform use of data sharing in routine pediatric diabetes care. RESEARCH DESIGN AND METHODS: Interviews with 33 parents of 30 children (aged 1-7 years) with type 1 diabetes participating in a randomized trial (KidsAP02) comparing hybrid closed-loop system use with sensor-augmented pump therapy. Data were analyzed using a qualitative descriptive approach. RESULTS: Parents reported multiple benefits to healthcare professionals being able to remotely access their child's glucose and insulin data during the trial, despite some initial concerns regarding the insights offered into everyday family life. Key benefits included: less work uploading/sharing data; improved consultations; and, better clinical input and support from healthcare professionals between consultations. Parents noted how healthcare professionals' real-time data access facilitated remote delivery of consultations during the COVID-19 pandemic, and how these were more suitable for young children than face-to-face appointments. Parents endorsed use of real-time data sharing in routine clinical care, subject to caveats regarding data access, security, and privacy. They also proposed that, if data sharing were used, consultations for closed-loop system users in routine clinical care could be replaced with needs-driven, ad-hoc contact. CONCLUSIONS: Real-time data sharing can offer clinical, logistical, and quality-of-life benefits and enhance opportunities for remote consultations, which may be more appropriate for young children. Wider rollout would require consideration of ethical and cybersecurity issues and, given the heightened intrusion on families' privacy, a non-judgmental, collaborative approach by healthcare professionals.


Assuntos
Diabetes Mellitus Tipo 1 , Pais , COVID-19 , Criança , Pré-Escolar , Atenção à Saúde , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glucose , Humanos , Lactente , Insulina/uso terapêutico , Pandemias , Pais/psicologia , Pesquisa Qualitativa , Ensaios Clínicos Controlados Aleatórios como Assunto
17.
Diabetes Res Clin Pract ; 187: 109877, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35469973

RESUMO

AIMS: To explore parents' experiences of using a hybrid closed-loop system (CamAPS FX) when caring for a very young child (aged 1-7 years) with type 1 diabetes. METHODS: Interviews with n = 33 parents of 30 children who used the system during a randomised controlled trial. Data analysis used a descriptive thematic approach. RESULTS: While some parents were initially reticent about handing control to the system, all reported clinical benefits to using the technology, having to do less diabetes-related work and needing less clinical input over time. Parents welcomed opportunities to enhance the system's efficacy (using Ease-off and Boost functions) as required. Parents described how the system's automated glucose control facilitated more normality, including sleeping better, worrying less about their child, and feeling more confident and able to outsource care. Parents also described more normality for the child (alongside better sleep, mood and concentration, and lessened distress) and siblings. Parents liked being able to administer insulin using a smartphone, but suggested refinements to device size and functionality. CONCLUSIONS: Using a hybrid closed-loop system in very young children can facilitate greater normality and may result in a lessened demand for health professionals' input. Systems may need to be customised for very young children.


Assuntos
Diabetes Mellitus Tipo 1 , Glicemia/análise , Criança , Pré-Escolar , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Pais , Pesquisa Qualitativa
18.
Lancet Digit Health ; 4(4): e245-e255, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35272971

RESUMO

BACKGROUND: Closed-loop insulin delivery systems have the potential to address suboptimal glucose control in children and adolescents with type 1 diabetes. We compared safety and efficacy of the Cambridge hybrid closed-loop algorithm with usual care over 6 months in this population. METHODS: In a multicentre, multinational, parallel randomised controlled trial, participants aged 6-18 years using insulin pump therapy were recruited at seven UK and five US paediatric diabetes centres. Key inclusion criteria were diagnosis of type 1 diabetes for at least 12 months, insulin pump therapy for at least 3 months, and screening HbA1c levels between 53 and 86 mmol/mol (7·0-10·0%). Using block randomisation and central randomisation software, we randomly assigned participants to either closed-loop insulin delivery (closed-loop group) or to usual care with insulin pump therapy (control group) for 6 months. Randomisation was stratified at each centre by local baseline HbA1c. The Cambridge closed-loop algorithm running on a smartphone was used with either (1) a modified Medtronic 640G pump, Medtronic Guardian 3 sensor, and Medtronic prototype phone enclosure (FlorenceM configuration), or (2) a Sooil Dana RS pump and Dexcom G6 sensor (CamAPS FX configuration). The primary endpoint was change in HbA1c at 6 months combining data from both configurations. The primary analysis was done in all randomised patients (intention to treat). Trial registration ClinicalTrials.gov, NCT02925299. FINDINGS: Of 147 people initially screened, 133 participants (mean age 13·0 years [SD 2·8]; 57% female, 43% male) were randomly assigned to either the closed-loop group (n=65) or the control group (n=68). Mean baseline HbA1c was 8·2% (SD 0·7) in the closed-loop group and 8·3% (0·7) in the control group. At 6 months, HbA1c was lower in the closed-loop group than in the control group (between-group difference -3·5 mmol/mol (95% CI -6·5 to -0·5 [-0·32 percentage points, -0·59 to -0·04]; p=0·023). Closed-loop usage was low with FlorenceM due to failing phone enclosures (median 40% [IQR 26-53]), but consistently high with CamAPS FX (93% [88-96]), impacting efficacy. A total of 155 adverse events occurred after randomisation (67 in the closed-loop group, 88 in the control group), including seven severe hypoglycaemia events (four in the closed-loop group, three in the control group), two diabetic ketoacidosis events (both in the closed-loop group), and two non-treatment-related serious adverse events. There were 23 reportable hyperglycaemia events (11 in the closed-loop group, 12 in the control group), which did not meet criteria for diabetic ketoacidosis. INTERPRETATION: The Cambridge hybrid closed-loop algorithm had an acceptable safety profile, and improved glycaemic control in children and adolescents with type 1 diabetes. To ensure optimal efficacy of the closed-loop system, usage needs to be consistently high, as demonstrated with CamAPS FX. FUNDING: National Institute of Diabetes and Digestive and Kidney Diseases.


Assuntos
Diabetes Mellitus Tipo 1 , Cetoacidose Diabética , Adolescente , Algoritmos , Glicemia/análise , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Cetoacidose Diabética/induzido quimicamente , Feminino , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Masculino
19.
Diabet Med ; 39(7): e14828, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35274356

RESUMO

AIMS: To explore parents' experiences of using remote monitoring technology when caring for a very young child with type 1 diabetes during a clinical trial. METHODS: Interviews were conducted with parents of 30 children (aged 1-7 years) participating in a trial (the KidsAP02 study) comparing hybrid closed-loop insulin delivery with sensor-augmented pump therapy. In both arms, parents had access to remote monitoring technology. Data analysis focused on identification of descriptive themes. RESULTS: Remote monitoring technology gave parents improved access to data which helped them pre-empt and manage glucose excursions. Parents observed how, when children were in their own care, they could be more absent while present, as their attention could shift to non-diabetes-related activities. Conversely, when children were others' care, remote monitoring enabled parents to be present while absent, by facilitating oversight and collaboration with caregivers. Parents described how remote monitoring made them feel more confident allowing others to care for their children. Parents' confidence increased when using a hybrid closed-loop system, as less work was required to keep glucose in range. Benefits to children were also highlighted, including being able to play and sleep uninterrupted and attend parties and sleepovers without their parents. While most parents welcomed the increased sense of control remote monitoring offered, some noted downsides, such as lack of respite from caregiving responsibilities. CONCLUSIONS: Remote monitoring can offer manifold benefits to both parents and very young children with type 1 diabetes. Some parents, however, may profit from opportunities to take 'time out'.


Assuntos
Diabetes Mellitus Tipo 1 , Pais , Tecnologia de Sensoriamento Remoto , Glicemia , Automonitorização da Glicemia , Criança , Pré-Escolar , Ensaios Clínicos como Assunto , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Lactente , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Pais/psicologia
20.
N Engl J Med ; 386(3): 209-219, 2022 01 20.
Artigo em Inglês | MEDLINE | ID: mdl-35045227

RESUMO

BACKGROUND: The possible advantage of hybrid closed-loop therapy (i.e., artificial pancreas) over sensor-augmented pump therapy in very young children with type 1 diabetes is unclear. METHODS: In this multicenter, randomized, crossover trial, we recruited children 1 to 7 years of age with type 1 diabetes who were receiving insulin-pump therapy at seven centers across Austria, Germany, Luxembourg, and the United Kingdom. Participants received treatment in two 16-week periods, in random order, in which the closed-loop system was compared with sensor-augmented pump therapy (control). The primary end point was the between-treatment difference in the percentage of time that the sensor glucose measurement was in the target range (70 to 180 mg per deciliter) during each 16-week period. The analysis was conducted according to the intention-to-treat principle. Key secondary end points included the percentage of time spent in a hyperglycemic state (glucose level, >180 mg per deciliter), the glycated hemoglobin level, the mean sensor glucose level, and the percentage of time spent in a hypoglycemic state (glucose level, <70 mg per deciliter). Safety was assessed. RESULTS: A total of 74 participants underwent randomization. The mean (±SD) age of the participants was 5.6±1.6 years, and the baseline glycated hemoglobin level was 7.3±0.7%. The percentage of time with the glucose level in the target range was 8.7 percentage points (95% confidence interval [CI], 7.4 to 9.9) higher during the closed-loop period than during the control period (P<0.001). The mean adjusted difference (closed-loop minus control) in the percentage of time spent in a hyperglycemic state was -8.5 percentage points (95% CI, -9.9 to -7.1), the difference in the glycated hemoglobin level was -0.4 percentage points (95% CI, -0.5 to -0.3), and the difference in the mean sensor glucose level was -12.3 mg per deciliter (95% CI, -14.8 to -9.8) (P<0.001 for all comparisons). The time spent in a hypoglycemic state was similar with the two treatments (P = 0.74). The median time spent in the closed-loop mode was 95% (interquartile range, 92 to 97) over the 16-week closed-loop period. One serious adverse event of severe hypoglycemia occurred during the closed-loop period. One serious adverse event that was deemed to be unrelated to treatment occurred. CONCLUSIONS: A hybrid closed-loop system significantly improved glycemic control in very young children with type 1 diabetes, without increasing the time spent in hypoglycemia. (Funded by the European Commission and others; ClinicalTrials.gov number, NCT03784027.).


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Controle Glicêmico/instrumentação , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Pâncreas Artificial , Algoritmos , Glicemia/análise , Criança , Pré-Escolar , Estudos Cross-Over , Desenho de Equipamento , Feminino , Hemoglobinas Glicadas/análise , Controle Glicêmico/métodos , Humanos , Hiperglicemia/diagnóstico , Lactente , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...